NEW 500kW Jichai 190 gas gensets PLG-500GF for sale
Best price on the market > Fast shipping > Guarantee > Lifetime service
ID/REF: 2804
Manufactured by: Jichai
The factory: Jichai
Category: Генераторные установки ГПУ на природном газе | Генераторные установки (ГПУ) на природном газе
International Certifications: EU, China, USA
Popularity: 77948 view
Manufactured by: Jichai
The factory: Jichai
Category: Генераторные установки ГПУ на природном газе | Генераторные установки (ГПУ) на природном газе
International Certifications: EU, China, USA
Popularity: 77948 view
NEW
Mileage Hrs/Kms: 0
Year of Manufacture: 2024
The price: P.O.A.
QTY Available in stock: 2
Year of Manufacture: 2024
The price: P.O.A.
QTY Available in stock: 2
WE offer: industrial NEW 190 series CNPC JICHAI 500GF-T, Jichai 500GF-T, 500 кВт, 4000 Series 500KW), CNPC JICHAI 500GF-T Natural Gas GenSet, NEW CNPC JICHAI LNG CNG Natural Methane Gas Generator Set, CNPC JICHAI natural gas generator sets, NEW CNPC JICHAI generator sets, 1MW NEW CNPC JICHAI gas generator sets, biomass gas generator sets, containerized gas generator sets, Dual fuel diesel&gas generator sets,hydrogen gas generator sets CHP unit,Powered by JICHAI natural gas 500GF-T,Weifang Engine,Man natural gas,Doosan natural gas, JICHAI engines 500GF-T, generator for Mines, JICHAI Building, Oil Fields, Hospitals, Schools, Ports, Hotels generator set, Natural Gas Genset, Biogas Genset, Gas Propane LPG Genset, Gas Land Fill Genset, Syngas Genset, Gas CHP and CCHP Unit Genset, Gas Dual Genset, JICHAI Gas Hydrogen Genset, 500 generator, lpg gas generator, JICHAI 500kw generator price lpg powered generator super silent lpg generator, best China electric generator 500kw, JICHAI 500kw genset.
cost industrial 500kW Jichai 190 gas gensets PLG-500GF. Cost Spare parts for 500kW Jichai 190 gas gensets PLG-500GF. Download Manuals PDF for 500kW Jichai 190 gas gensets PLG-500GF. Manuals for 500kW Jichai 190 gas gensets PLG-500GF
Maintenance 500kW Jichai 190 gas gensets PLG-500GF for sale USA, UK, France, Africa, Ghana, Nigeria, Qatar, Ukraine, Russia, Turkey and standby 500kW Jichai 190 gas gensets PLG-500GF
NOTICE
Please don't copy or download any of these photos for posting on the Internet or for promotional use. Please send us a personal message if you would like to use them.
Please don't copy or download any of these photos for posting on the Internet or for promotional use. Please send us a personal message if you would like to use them.
The data sheet of the NEW 500kW Jichai 190 gas gensets PLG-500GF
Factory Direct
Fast shipping
Full warranty and spare parts
NEW 500kw Jichai 190 series gas generator sets PLG-500GF
190 Series gas engines are developed by cooperation with AVL from Germany and Austria. The engine assembling plant is affiliated
to CNPC (China National Petroleum & Oil Corporation), those engines work extensively in 90% of China oil fields and coal mines,
and enjoy hot markets in global.
Rated power(kW/kVA) kW kVA 500/625
Rated voltage(V) 400
Fuel: LNG, CNG, Natural Gas
All ratings data is based on operation under IS08528 standard.
Both 50Hz .
Jichai - ONE YEAR UNLIMITED WARRANTY
Feature of the 190 series gas generator sets
Long service life resulting from application-specific design
Lower operating and maintenance costs
Low emissions due to advantage technologies
Reliable in field-tested
Adapt to harsh conditions
Benefits of HAITAI Power-CNPC 190 Series gas engines & Genset
1. The engine performance is Leading China and First class Global
2. Long history: produced by engines plant under control by CNPC (China National Petroleum & Oil Corporation), it is the first and
the largest engine manufacture in China since 1953.
3. Proven Technology: widely used in 90% of China Oil & Gas Fields, Coalmines, Vessels and other areas under severe working conditions.
4. Fuel flexibility: designed for operation on a wide range of methane based gases including natural gas, biogas, oilfield gas, coal
mine methane and shale gas and other special gas.
5. Designed for intensive use (continuous duty)
6. Capable of working with variable loads.
7. Advanced technology of close-loop control, lean-burn and Mixing before turbo.
8. Adopting highly intelligent gas control system of Woodward EGS or Motortech, the air fuel ratio can be automatically adjusted
as per fluctuation of gas components.
9. Adopting intelligent & digital ignition system from Motortech or Altronic.
10. Adopting super-turbocharged technology from ABB.
11. Heat Recovery system to realize CHP, Cogeneration and Distribution Energy.
12. Integrated & modularized unit to facilitate easy transport and quick setup. Easy Maintenance in Low Cost.
14. Ensured annually continuous working over 8760 hours.
15. Longer life span of 20-25 years.
Jichai ADDITIONAL FEATURES
Customisable status screens.
Multiple date & time scheduler.
Charge alternator failure alarm.
CAN engine manual speed control.
Manual fuel pump control.
Engine exerciser.kW & kV Ar overload protection.
Reverse power (kW & kV Ar) protection. Unbalanced load protection.
USB connectivity.
Backed-up real time clock.
Configurable Gencomm pages.
SMS messaging start & stop functionality.
Modem diagnostic display screens.
Remote display support (max 3 units)
Jichai PowerKit Gas Engine Datasheet
Ratings Definitions - COP
- Unlimited using time per year;
- Continuous power is the maximum power available at a constant load factor;
- No overload capability is allowed
Ratings Definitions - PRP
- Unlimited using time per year;
- The average load rate is no more than 70% over 24 hours;
- Overloading 10% for 1h within 12 hours of operation is allowed.
Ratings Definitions - ESP
- he annual operating time shall not exceed 200h;
- The average load rate shall not exceed 70% over24h operation cycle;
- No overload capability is allowed;
- The acceleration of starting of engines are carried out in accordance with
Q/WCG136.13, and theres no engine process. From acceleration of starting to calibration speed shall be completed within 10s. Natural aspirated engine,
when the environment temperature is below 5°, need to increase preheat facilities to ensure that engine water temperature above 30°. When
environment temperature over 5°, no preheating facilities are required.
Supercharged engine, when the environment temperature is below 10°, need to increase preheat facilities to ensure that engine water temperature
above 30° When environment temperature over 10°, no preheating facilities are required
LTP- No ability to overload;
- The annual operating time shall not exceed 500h while supplying a variable
electrical load.
DCP- It has 10% overload capacity;
- Annual run time is unlimited;
- Working under variable or continuous load of less than 100%;
- The power load shall not exceed 70% of the calibration power when the device is running continuously.
Descriptions- ISO 8528-1, ISO 3046, DIN6271+-5%
- All ratings are based on operating conditions under ISO 8528-1,ISO 3046, DIN6271. Performance tolerance of+-5%.
- Test conditions : 100 kPa, 25°C air inlet temperature, relative humidity of
30%. Derating may be required for conditions outside these; please contact the factory for details. - Power output curves are based on the engine operating with gas system, water pump and lubricating oil pump, without battery charging alternator,
fan and optional equipment
General Container
Structural design description:
The internal space is divided into two spaces: engine room and control room, and inspection channels on both sides of the equipment inside the engine room.
Functional description:
1)The container is equipped with a distribution box to provide power to all low-voltage loads in the engine room, such as horizontal radiator fans, control screens, lighting, exhaust (supply) fans (for horizontal distribution), chargers, electric heating (optional), oil pumps, electric heating (optional), and outdoor searchlights. It can also be responsible for controlling related equipment (according to project configuration requirements);
2)Two track suspension beams and a hoist are installed on the top of the engine room, with a lifting capacity of 0.5 tons per beam;
3)Inlet of engine air filter and the engine room are equipped with electric heating devices to avoid freezing and blockage (optional);
4)The floor of the machine room is equipped with an axial drive mechanism for the generator, which enables the generator to detach from the coupling by 200mm. (Optional)
5)If the indoor heating temperature in the machine room is not lower than 5 C deg., an insulation layer needs to be installed under the chassis of the machine room, and electric heating heaters (optional) are used inside the machine room;
6)One explosion-proof acoustic and visual alarm lamp is installed outside each machine room. The lighting inside the machine room is an explosion-proof LED lamp with emergency function. Other equipment and boxes do not need to be explosion-proof (optional).
7)Ladder: Install a simple ladder at a suitable position on the box;
8)Configure the fire protection system in the machine room: Install dry powder fire extinguishers as fire extinguishing devices (standard), and other flame detectors, methane leak detectors, smoke detectors, etc. as optional options;
9)Note: The specific configuration shall be subject to the actual situation of the project.OPTIONS
CHP system (Exhaust Heat Collector) CHP/ Cogeneration/ CCHP/ Trigeneration
1. The unique spiral winding structure increases the turbulence effect, and the heat exchange capacity per unit area is 3-7 times that of the traditional heat exchanger.
2. High heat transfer coefficient, high heat exchanger heat transfer efficiency, good heat transfer effect, high heat transfer coefficient up to 14000W/mВ·k, energy saving effect is remarkable.
3. Small size. With only one-tenth of the traditional tube and shell heat exchangers, it takes up less space and reduces infrastructure and installation and maintenance costs.
4. Using a small clearance design to increase the flow rate, the heat exchanger is not easy to foul, and the use and maintenance costs
are low.
5. Advanced design concept, the length of the heat exchange tube is 3-4 times the height of the cylinder, the material stays longer and the
heat transfer is more fully.
6. Spiral-wound elastic tube bundle design can effectively eliminate pipe vibration and stress due to thermal expansion and contraction deformation.
7. Unique 90 degree connection, heat exchangers all participate in heat exchange,
no dead ends and stagnant areas, reduce fluid resistance.
8. Counter-current heat transfer, asymmetric flow design, in the vapor-liquid heat transfer field has other advantages that can not be compared with heat exchangers.
Automatic Paralleling and Gridconnect Control System
This system can connect generator sets in parallel or connect the generator set to the grid automatically.
Remote Control
PMG Alternator
Oil and Water Heater
High Voltage Alternator 6.3kv and 10.5kv, High Voltage Electrical Control Cells (PT Cabinet)
CT Cabinet
High Voltage outgoing cabinet
DC Panel, Groud Resistance Cabinet and low voltage distribution cabinet etc)
The specification of the 500kW Jichai 190 gas gensets PLG-500GF
Model of genset HTG-500GF
Model of engine 12V190ZDT1-2
Coupling method Elastic coupling
Rated speed(r/min) 1000
Rated power(kW/kVA) 500/625
Rated voltage(V) 400
Rated frequency(Hz) 50
Rated power factor 0.8 lagging
Governor WOODWARD
Electronical
Voltage regulation Automatic
Supply connecting 3 phase 4wire
Control model Remote electric control, Hand control
Starting method 24V DC electric starting motor
Cooling method Water cooling system, open type
Overall dimension
L×B×H(mm) 4770×2200×2778mm
Net weight(kg) 11800
Main Specification of Engine
Model of engine 12V190ZDT1-2
Rated Power 550kW
No. and layout of cylinders 12, 60°Vee
Type Four stroke, water cooled, turbocharged and aftercooled, spark plug ignition, outer mixing
Speed(r/min) 1000
Specific heat consumption (kJ/kW.h) ≤11000
Specific oil consumption (g/kW.h) ≤1.6
Idle speed(r/min) 700
Bore 190mm
Stroke 210mm
Compression ratio 12:1
Direction of rotation Counter-clockwise(facing to flywheel)
Lubrication method Pressure and splash lubrication
Stable speed regulating rate 0~5% adjustable
Gas inlet pressure 5-12 kPa
Gas filters Including
Air filters Including
Lubricating oil consumption ≤1.0g/kW.h
Oil filters Including(Dual filtration system )
Exhaust Temperature ≤650℃
Speed Governor Electronic
Air fuel ratio control mode EGS automatic control A/F
Cooling Method Forced water cooling
Noise <120db
Explosion protection Including(90C°Alarm)
High temperature protection of lubricating oil Including(95C°Alarm)
Low lubrication oil pressure protection ≤250+-20kPa Alarm ≤200+-20kPa Auto stop
Overspeed protection ≥112%+-1% Alarm ≥115%+-1% Auto stop
Engine data acquisition Including(configured RS485 interface )
Silencer type Fire extinguishing exhaust muffler
Crankshaft Rotation Direction Inverse Hour (From Flywheel)
Technical Data of Alternator
Type
1FC5 456-6TA42
(SIEMENS technic)
Rated power(kW/kVA) 500/625
Rated voltage(V) 400
Rated frequency(Hz) 50
Exciting method Brushless
Wiring method 3 phases, 4 wires
Number of pole 6
Rated speed 1000 r/min
Insulation class Class F
Class of protection IP23
Cooling A fan at the drive end draws the cooling air
Type and number of bearing Rolling bearing, 2 pcs
Coupling Elastic
Decontamination Requirement of Natural gas
Composition Oil、 No liquid state
Dust <10 mg/m3
Dust Granularity <50μm
Sulfide <20 mg/m3
Generators » Standart Supply Scope
Generators » All Optional parts
Generators » Control Panels - No ability to overload;